Specifications | |
ECG | |
Lead type | 3-lead or 5-lead selectable |
Lead selection, 3-lead | I, II, III |
Lead selection, 5-lead | I, II, III, aVR, aVL, aVF, V |
HR measurement | Adult / pediatric: 15 bpm – 300 bpm Neonatal: 15 bpm – 300 bpm Step: 1 bpm |
HR accuracy | ±5 bpm or ±1 %, whichever is greater |
Arrhythmia | 21 calls |
ST measurement range | -2.5 mV – +2.5 mV |
Waveform speed | 6.25 mm/s,12.5 mm/s, 25 mm/s, 50 mm/s |
Gain selection | x 1/4, x 1/2, x 1, x 2, x 4, Auto |
Pacemaker detection | Yes |
Protection | Against electrosurgical interference and defibrillation |
Non-invasive blood pressure (NBP) | |
Method | Automatic oscillometric |
Parameters | SYS/DIA/MAP/Pulse Rate |
Operating mode | Manual/Auto/STAT |
Auto measure intervals | 3, 5, 10, 15, 30, 60, 90, 120, 240, 480 minutes |
Units | mmHg/kPa |
Cuff pressure range, adult / pediatric | 0 – 300 mmHg ( 0 kPa – 40.0 kPa) |
Cuff pressure range, neonate | 0 – 150 mmHg ( 0 kPa – 20.0 kPa) |
Systolic measurement range, adult/ pediatric | 30 mmHg – 254 mmHg (4.0 kPa – 33.9 kPa) |
Systolic measurement range, neonate | 30 mmHg – 135 mmHg (4.0 kPa – 18.0 kPa) |
Diastolic measurement range, adult / pediatric | 10 mmHg – 220 mmHg (1.3 kPa – 29.3 kPa) |
Diastolic measurement range, neonate | 10 mmHg – 110 mmHg (1.3 kPa – 14.7 kPa) |
MAP measurement range, adult / pediatric | 20 mmHg – 235 mmHg (2.7 kPa – 31.3 kPa) |
MAP measurement range, neonate | 20 mmHg – 125mmHg (2.7 kPa – 16.7kPa) |
Accuracy, maximum standard deviation | 8 mmHg (1.1 kPa) |
Accuracy, mean error | ±5 mmHg (±0.7 kPa) |
Pulse rate range | 40 bpm – 240 bpm |
Pulse rate accuracy | ±5bpm or ±5%, whichever is greater |
SpO2 (Philips SpO2 technology) | |
Measurement range | 0 – 100 % |
Accuracy | 70 % – 100 %, depends on sensor; 0 – 69 %, unspecified |
Waveform speed | 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s |
Pulse rate range | 30 bpm – 300 bpm |
Pulse rate accuracy | ±2 bpm or ±2%, whichever is greater |
Perfusion index | Yes |
Respiration (RESP) | |
Measurement method | Thoracic impedance |
Measurement range | 0 rpm – 150 rpm |
Accuracy | 0rpm – 120rpm: ±1 rpm; 121rpm – 150rpm: ±2 rpm |
Waveform speed | 6.25 mm/s,12.5 mm/s, 25 mm/s, 50 mm/s Accuracy undefined |
Gain selection | x 1/2, x 1, x 2 |
Apnea alarm | Yes, 10 – 60 s |
Work mode | Auto or manual (threshold) |
RESP lead | RA-LL |
Temperature (TEMP, 2-channel) | |
Measurement range | 0 – 50℃ (32℉ – 122℉) |
Resolution | 0.1℃ (0.2℉) |
Accuracy | ±0.1℃ (±0.2℉) (without sensor) |
Units | ℃ / ℉ |
Minimum measuring time | Attachable skin surface probe: less than 10 minutes Esophageal/rectal probe: less than 2 minutes |
Capnopgraphy (etCO2, optional) | |
Method | Microstream, infrared absorption (Oridion) |
Parameters | awRR, etCO₂, inCO₂ |
Measurement range | 0 – 99 mmHg (0 kPa – 13.2 kPa) |
Accuracy+C781, 0 – 38 mmHg (0 kPa – 5.1 kPa) | ±2 mmHg (±0.28 kPa) |
Accuracy, 39 mmHg – 99 mmHg (5.2 kPa – 13.2 kPa) | ± (5% of reading + 0.08% for every 1 mmHg (0.13 kPa) above 38 mmHg (5.1kPa) |
awRR range | 0-150 rpm |
awRR accuracy, 3 rpm – 70 rpm | ±1 rpm |
awRR accuracy, 71 rpm – 120 rpm | ±2 rpm |
awRR accuracy, 121 rpm – 150 rpm | ±3 rpm |
Invasive Blood Pressure | |
Accuracy | ±4 mmHg (0.53 kPa) or ±4 % of reading, whichever is greater |
Invasive blood pressure (IBP, 2-channel, optional) | |
Parameters | SYS/DIA/MAP/Pulse Rate |
Measurement range | -50 – 400 mmHg (-6.6 kPa – 53.3 kPa) |
Waveform speed | 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s |
Resolution | 1 mmHg (0.13 kPa) |
Units | mmHg/kPa/cmH₂O |
Transducer sensitivity | 5 uV/V/mmHg |
Pulse rate range | 30 bpm – 254 bpm |
Pulse rate accuracy | ±2bpm or ±2%, whichever is greater |
Sampling rate | 62.5 samples per second |
Recorder (optional) | |
Type | Built-in thermal recorder, 3 channels |
Print mode | Real-time recording, timed recording, alarm-activated recording |
Print speed | Auto, 12.5 mm/s, 25 mm/s, 50 mm/s |
Display | |
Type | Color TFT LCD, 4:3 |
Size | 10.4+611:631″ |
Resolution | 800 x 600 pixels |
Channels | Max 11 channels (auto waveform channel height adjustment) |
Power supply | |
AC power input | 100 – 240 VAC, 50/60 Hz |
Battery | Rechargeable Li-Ion battery Maximum 2.5 hour continuous monitoring (1 battery) |
Weight and dimensions | |
Net weight | Approx. 3.5 kg without battery |
Dimensions (w x d x h) | 316 mm x 265 mm x 131 mm (12.5 in. x 10.5 in. x 5.2 in.) |
Safety approval and quality system | |
Safety standard | IEC 60601-1-2:2014 |
Electromagnetic environment | IEC 60601-1-2:2000/A1:2014 |
Quality system | ISO9001 & ISO13485 certified CE marking according to the Council Directive 93/42/EEC |
Water proof | IPX1 |
Data review and storage | |
Data review and storage | 1600- NBP data, 1200 hr trend graph, 120 min full disclosure ECG 1, 200 – alarm & arrhythmia events |
External interface (standard) | |
External interface | ECG analog output VGA output Nurse call LAN USB |
Cardiac Output (optional) | |
Measurement method | Right heart thermodilution |
Measurement range | 0.1 l/min – 20.0 l/min |
Measurement accuracy | ±0.2 l/min or ±10 %, whichever is greater |
Blood temperature range | 27℃ – 43℃ (80.6℉ – 109.4℉) |
Blood temperature accuracy | ± 0.1℃ |
Injection temperature | 0℃ – 27℃ (32℉ – 80.6℉) |
Advanced functionalities
The G20 provides real-time data on cardiac and respiratory conditions in order to fit different clinical settings. As well as specific monitoring parameters such as Philips ST / AR 3-and5-lead ECG/ respiration, NBP, 2 temperatures, and Philips SpO2/PR, ST and arrhythmia monitoring, it also offers options for 2-channel intrusive blood pressure and Microstream etCO2 monitoring.
Ease of use
The monitor has a 12.1 “display with flexible display modes such as large number display, minitrend, OxyCRG, and the height adjustment function of the auto waveform channel to fit different clinical settings. For maximum ease of use, intuitive menus, fixed key access, bright color screen, and optional touchscreen have all been designed.
Networking and data management
The G40E comes standard with LAN networking capabilities for facilities that seek to create a bi-directional communication network with a central monitoring system from Philips Efficia CMS200 or require data output in HL7 format.
Compact and cost-effective
The G40E patient monitor, designed in compliance with Philips ‘ exacting quality standards, offers market-proven critical parameters in a lightweight, cost-effective display to produce precise measurement results on your tight budget. The role of an alarm clock helps to reduce alarm fatigue in order to create a quiet care environment.
Works with Efficia consumables
The G40E patient monitor is designed to be compatible with consumables from Philips Efficia, which are also used on patient monitors from the Philips Efficia CM series, to reduce your total cost of ownership by sharing consumables from Philips across various care settings.